Difficulty in Removal Of Built up Finish

– Improper detailing of edges, corners and / or higher traffic areas at time of initial strip and re-coat.
– If practical, spot strip affected areas and re-coat the patched up areas with 3 or more coats then burnish blend the last (third) coat on the edge (s). Add more coatings as necessary.
– Re-strip and re-coat floor using appropriate procedures.
– Always do stripper pre-test in several different representative areas to determine your proper dilution ratio.
1. Strip pad or brush used NOT aggressive enough
– Use ONLY Hi-Pro super-strip type stripping pad or Strato grit brush for flooring with grout. Some operations require both. Test for best results.
2. Semi-permanent seal was used on floor.
– Re-strip and re-coat floor using appropriate procedures
3. Stripping brush was used instead of Hi-Pro strip pad.
– Use ONLY Hi-Pro super-strip type stripping pad or Strato grit brush for flooring with grout. Some operations require both. Test for best results.
4. Insufficient dwell time of ‘Striper’ or ‘Cleaner & Conditioner and/or too weak dilution for the task, soil load or finish load.
– Extend dwell time.

Posted in: FAQs